9.4.3 Changing Master Parameters
Usually there is no need to change these parameters. This is because the DeviceNet
master automatically detects the network status and writes the typical parameters.
Only when you need to change the EPR or ISD, change these parameters. For
example, you need to decrease the EPR value in order to shorten the disconnection
detection time.
To make master parameters revert to the original after change, enter “0.”
Do not change serial numbers.
What is “EPR” (Expected Packet Rate)?
This value is the basis for judging a “timeout” when the slaves communicate with the
master (polling or bit strobe). If there is no access from the master during the set
time, then the slave times out and an error status is established. For the master, this
value is the setting for the disconnection detection time.
The relationship is: Detection time = EPR value × 4 (ms)
Note that if a too small value is entered, the “No response from slave” error will occur
even in normal status.
What is “ISD” (Inter Scan Delay)?
This is the interval between the scan cycles in which the master scans the slave
devices.
Step 1
On the Auxiliary Function (I/O) screen, press [F8 MasterPrm].