Denso RC5 Especificaciones Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
93
Details of errors and the meanings of flags are given below.
Error No. Error Details
0x01 I/O area duplicated
0x02 Out of I/O area
0x03
Configuration error
Unsupported slave detected
0x04 No registered slave
0x05
Collation error
Slave I/O size mismatch
0x06 Communication error (communication timeout)
0x10 Node address double-assigned
0x11 Busoff detected
0x20 Network power supply error
0x21
Transmission error
Transmission timeout
0x30 RAM error
0x31 ROM error
0x32 DPRAM error
0x33
Memory error
DPRAM retry error
0x34 Serial number error
0x35 EPR error
0x36 ISD error
0x37
Flash ROM error
Scanlist error
0x41 Robot setting bit error
Scanlist make failure:
Shows that an error has occurred during creation of a scanlist.
Scanlist/SerialNo operation failure:
Shows that there is an error in the scanlist/serial number data.
Scanlist preparation not finished:
Shows that the scanlist is still being created.
I/O Communication is up:
Shows that the master is normally communicating with the slaves.
Scanlist already set up:
Shows that a scanlist already exists in the memory of the master.
Serial No determined:
Shows that a serial number already exists in the memory of the master.
Vista de pagina 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 137 138

Comentarios a estos manuales

Sin comentarios