Communication protocols
You can select either no protocol mode or ACK/NAK mode.
No protocol mode (default)
If the CTS signal is at a high level (Enable transmission), the scanner transmits barcode data read.
Note: The configuration software (Scanner Setting) provides CTS timeout settings from 100 ms to
9.9 s in 100-ms increments and two CTS signal control choices “controlled” and “not controlled.”
ACK / NAK mode
If the CTS signal is at high level (Enable transmission), the scanner transmits barcode data read. After that, the
scanner waits for and then processes a response. If the response is an ACK, the scanner normally ends the
transmission; if it is a NAK, the scanner transmits the barcode data again.
Note: The configuration software (Scanner Setting) provides CTS timeout and ACK/NAK response settings
each from 100 ms to 9.9 s in 100-ms increments.