7.2 Data Editing
You can edit and output code data read, in any of the three data edit modes--“data extraction mode,” “data
conversion mode” and “blocksorting mode.” These data edit modes can be selected with the configuration
software (Scanner Setting). The default is “No editing.”
7.2.1 Data extraction mode
This mode offers three extraction choices--“data string,” “data block” and “AI (Application Identifier)-prefixed
string” extractions from code data read and then outputs it.
The “data block” extraction is available only when code data is in the comma-delimited CSV format.
The “AI-prefixed string” extraction is available for GS1-128 (EAN-128) and GS1 DataBar (RSS) symbols.
7.2.1.1 Extracting a data string
The scanner extracts a data string specified by the “Extraction start position” and “Extraction end position” from a
code specified by the “Code type” and then outputs it in the data transmission format selected in the scanner (see
Chapter 9, Section 9.4). The extraction conditions and extraction start and end positions are listed below.
Extraction conditions
Extraction conditions Setting data
Any code
UPC-A/EAN-13
UPC-E
EAN-8
CODE128
GS1-128 (EAN-128)
CODABAR (NW-7)
CODE39
Interleaved 2 of 5(ITF)
Standard 2 of 5(STF)
CODE32
CODE93
MSI
Plessey
“Code type”
GS1 DataBar (RSS)
“Transmit data regardless of the results” Permit / Prohibit
If the scanner fails to extract a data string or scans a code not specified by “Code type” when the “Transmit data
regardless of the results” is permitted, then it outputs the data read as is without editing.