83
2D Code Handy Terminal
“3:CODABAR”:Detailed settings for Codabar (NW-7)
1. Select “3: CODABAR” at SET BARCODE menu and then press the
ENT key.
SET CODABAR screen displays.
“1:MIN”:
Set minimum number of digits of Codabar
Setting range: 3~99
“2:MAX”:
Set maximum number of digits of Codabar
Setting range: 3~99
━ Point ━ Set the value of minimum number of digits less than that of maximum number of digits. If the
value of minimum munber of digits is larger than that of maximum munber of digits, erro
occurs when reading.
“3:START CODE”:
“4:STOP CODE”:
Allocate “?,A, B, C, D” to start/stop code of Codabar.
If “A, B, C, D” is allocated at the menu, limitation can be set to read only when allocated characters
matchs to the characters of CODABAR. It can read umlimitedly when “?” is allocated.
“5:CD CHECK”:
“ON” :It reads only when check digits are correct. It doesn’t read when check digits are not corrct
or no check digits are found.
“OFF”:It reads whether check digits are found or not.
2. Use the cursor keys ([▲] [▼]) or numerical keys ([1] [2] [3] [4] [5]) to select the item to be set.
3. Use the cursor keys ([◄] [►]) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET
BARCODE screen.