Denso BHT-825QW Manual de usuario Pagina 98

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 253
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 97
83
2D Code Handy Terminal
“3:CODABAR”Detailed settings for Codabar (NW-7)
1. Select “3: CODABAR at SET BARCODE menu and then press the
ENT key.
SET CODABAR screen displays.
1MIN”
Set minimum number of digits of Codabar
Setting range 399
“2MAX”
Set maximum number of digits of Codabar
Setting range 399
Point Set the value of minimum number of digits less than that of maximum number of digits. If the
value of minimum munber of digits is larger than that of maximum munber of digits, erro
r
occurs when reading.
“3START CODE”
“4STOP CODE”
Allocate “?A, B, C, D” to start/stop code of Codabar.
If “A, B, C, D” is allocated at the menu, limitation can be set to read only when allocated characters
matchs to the characters of CODABAR. It can read umlimitedly when “?” is allocated.
“5CD CHECK”
“ON” It reads only when check digits are correct. It doesn’t read when check digits are not corrct
or no check digits are found.
“OFF”It reads whether check digits are found or not.
2. Use the cursor keys ([] []) or numerical keys ([1] [2] [3] [4] [5]) to select the item to be set.
3. Use the cursor keys ([] []) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET
BARCODE screen.
Vista de pagina 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 252 253