93
2D Code Handy Terminal
“3:MAX”:
Set the maximum code version of square Data Matrix Code.
Setting range: 1~24
(Recatangular Data Matrix setting)
“4:READING”:
Enable/disable recatangular Data Matrix
“5:MIN”:
Set the minimum code version of recatangular iQR Code.
Setting range: 1~6
“6:MAX”:
Set the maximum code version of recatangular Data Matrix.
Setting range: 1~6
━ Point ━ z Set the value of minimum code version to less than that of maximum code version. If the
value of minimum code version is larger than that of maximum code version, error occurs
when reading.
z Set the minimum/maximum code version within the setting range listed above. If the value
is out of the setting range, error occurs.
2. Use the cursor keys ([▲] [▼]) or numerical keys ([1] [2] [3] [4] [5] [6]) to select the item to be set.
3. Use the cursor keys ([◄] [►]) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET 2D
CODE screen.
“4:PDF417”:Detailed settings for PDF417
1. Select “4:PDF417” at SET 2D CODE menu and then press the ENT
key.
SET PDF417 screen displays.
(PDF417 setting)
“1:READING”:
Enable/disable PDF417.
(Micro PDF417 setting)
“2:READING”:
Enable/disable Micro PDF417
2. Use the cursor keys ([▲] [▼]) or numerical keys ([1] [2]) to select the
item to be set.
3. Use the cursor keys ([◄] [►]) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET 2D
CODE screen.