Denso BHT-825QW Manual de usuario Pagina 251

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 253
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 250
236
BHT-825Q series
Error No. Cause Details Remedy
The Transfer Utility “Communication port”
option specification is illegal.
Specify the communication port to which the BHT is
connected for the “Communication port” option.
The transmission speed at the BHT and PC
does not match.
Ensure that the transmission speed at the BHT and
PC matches.
Please be aware that the default transmission
speed differs depending on the BHT used.
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
The PC communication port setting is illegal. Enable “Use FIFO buffer. (16550 interchangeable
UART required.) (U)” setting for the communication
port used.
Hardware malfunction Please contact your dealer.
53
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
55
An attempt was made to download a file with
field width differing from that of the data file
already existing in the BHT.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
55
71
Illegal characters have been used in the file
name.
Change the file name.
Refer to QBdirect (page 237, Note 1) for details of
characters that can be used in file names.
75
The USB-COM port drive has been
incorrectly installed.
Reinstall the USB-COM port driver.
91
Illegal field information specification option
when transmitting data file.
Set a correct value for the field information option.
An attempt was made to download a file with
field width differing from that of the data file
already existing in the BHT.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
The size of the file being downloaded
exceeds the size of the available space in
the BHT user area.
Reduce the file size or delete any unwanted files in
the BHT.
91
Illegal characters have been used in the file
name.
Change the file name.
Refer to QBdirect (page 237, Note 1) for details of
characters that can be used in file names.
Other
BHT-Ir/BHT protocol was used for transfer
for a BHT-BASIC 4.0 format program file
(*.PD4).
Use Ymodem protocol or convert program files
to ”*.PD3”.
51