A user program returns the BHTs ID number which is required for the use of the BHT-Ir
protocol. The ID number is expressed by two bytes: lower byte on port 6061h and upper
byte on port 6062h. The range of the returned value is from 1 to FFFFh. If the ID number
is 1234h, for example, the value on 6061h is 34h and that on 6062h is 12h.
*15
If the value of this bit is 0 (standard-size), characters will be displayed as follows:
If the value of this bit is 1 (small-size), characters will be displayed as follows:
(W) x (H)
Single-byte ANK mode 6 dots x 8 dots
Two-byte Kanji mode Full-width
Half-width
16 dots x 16 dots
8 dots x 16 dots
(W) x (H)
Single-byte ANK mode 6 dots x 6 dots
Two-byte Kanji mode Full-width
Half-width
12 dots x 12 dots
6 dots x 12 dots