289
COMn
COMn
is a communications device file name.
For the BHT-3000 which supports both the optical and direct-connect interfaces
and can open them concurrently, you can set both "COM1:" and "COM2:".
For the BHT-4000/BHT-5000/BHT-6000/BHT-6500/BHT-7000/BHT-7500 which
supports both the optical and direct-connect interfaces but cannot open them
concurrently, you should set one of the specifications listed above. If you
attempt to open both interfaces concurrently, a run-time error will occur.
*3
The default interface refers to an interface which is selected on the Set Com menu (BHT-3000),
on the SET COM ENVIRONMENT menu (BHT-4000), on the SET COMMUNICATION menu
(BHT-5000/BHT-7000/BHT-7500), or on the SET COM menu (BHT-6000/BHT-6500) in System
Mode. (For details, refer to the BHT Users Manual.)
The BHT-6000/BHT-6500/BHT-7000/BHT-7500 cannot open the optical inter-
face and the bar code device file concurrently. If you attempt to open them con-
currently, a run-time error will occur.
COM may be in lowercase as shown below.
OPEN "com:" AS #8
baud
In the BHT-3000/BHT-4000/BHT-5000, baud is one of the baud rates: 38400*,
19600, 9600 (default), 4800, 2400, 1200, 600, and 300. (*The 38400 bps is sup-
ported by the direct-connect interface of the BHT-3000/BHT-4000 and by the
BHT-5000.)
In the BHT-6000/BHT-6500, when the optical interface is used,
baud is one of
the baud rates: 115200, 57600, 38400. 19200, 9600 (default), and 2400. When
the direct-connect interface is used, it is one of the baud rates: 38400, 19200,
9600 (default), 4800, 2400, 1200, 600, and 300.
In the BHT-7000/BHT-7500, when the optical interface is used,
baud is one of
the baud rates: 115200, 57600, 38400, 19200, 9600 (default), and 2400. When
the direct-connect interface is used, it is one of the baud rates: 115200, 57600,
,38400, 19200 (default), 9600, 4800, 2400, 1200, 600, and 300.
parity
parity
is a parity check. It should be N (default), E, or O, which corresponds
to None, Even, or Odd parity, respectively.
charalength
charalength
is a character length or the number of data bits. It should be 8
(default) or 7 bits.
Interface Communications device file name
Optical interface "COM1:"
Direct-connect interface "COM2:"
Default interface
*3
"COM:"
Vista de pagina 297