Denso Power Net Terminal BHT-7500 Especificaciones Pagina 497

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 560
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 496
488
D3. BHT-5000
Input Ports
A user program can monitor the hardware status through the input ports by using the WAIT
statement or INP function. BHT-BASIC defines each of these ports as a byte. The table
below lists the input ports and their monitoring function in the BHT.
*1
BHT-BASIC represents the bit order by the exponent of each binary digit in the byte. For
example, bit 0 means LSB; bit 7 means MSB.
*2
During the optical interface operation, a user program can monitor CS (CTS) signal. If CS
signal is received, bit 7 of this byte goes ON (1).
Port No. Bit assignment
*1
Monitors the following:
00
1
2
3
4
5
6
7
Keyboard buffer
Barcode buffer
Trigger switch
Receive buffer
Value of
TIMEA function
Value of
TIMEB function
Value of TIMEC function
CS (CTS) signal
*2
0: No data
0: No data
0: OFF
0: No data
0: Nonzero
0: Nonzero
0: Nonzero
0: OFF or file closed
1: Data stored
1: Data stored
1: ON
1: Data stored
1: Zero
1: Zero
1: Zero
1: ON
3 2-0 LCD contrast level
*3 *4
0 to 7 (0: Lowest, 7: Highest)
4 0 Message version
*4 *5
0: Japanese 1: English
5 0 Alphabet entry function 0: Disabled 1: Enabled
80
1
2
3
Wakeup function
Initiation of BHT
*6
TIME$ function
Wakeup time
0: Deactivated
0: Initiated by the
power key
0: System time
selected
0: Not set
1: Activated
1: Initiated by the
wakeup function
1: Wakeup time
selected
1: Set
Eh 0 System status indication
*4*7
0: OFF 1: ON
Fh 7-0 Re-read prevention enabled time
*8
0 to 255
10h-40Fh 7-0 VRAM
*4 *9
0: OFF 1: ON
6010h
6011h
7-0
0
Battery voltage level
*10
Battery type
0 to 255
0: Rechargeable
battery cartridge
1: Dry battery car-
tridge
6040h 0
1
Magic key 1
Magic key 2
0: Released
0: Released
1: Held down
1: Held down
6050h 0 Keyboard type 0: 26-key pad 1: 32-key pad
6060h 7-0 Communications protocol
*11
0: BHT-protocol 1: Multilink protocol
6061h
6062h
7-0
7-0
ID (lower byte)
*12
ID (upper byte)
*12
0 to 255
0 to 255