319
At program startup, the defaults--single-byte ANK mode and normal display--are
active.
If a parameter is omitted, the corresponding screen mode or character attribute
does not change.
In the two-byte Kanji mode, characters can be displayed in either the full-width
size (16 dots wide by 16 dots high) or the half-width size (8 dots wide by 16 dots
high). In the BHT-6000/BHT-6500/BHT-7000/BHT-7500, if the small-size font is
selected, characters will be displayed in either the full-width size (12 dots wide by
12 dots high) or the half-width size (6 dots wide by 12 dots high).
In the condensed two-byte Kanji mode (supported by the BHT-4000/BHT-5000),
characters can be displayed in either the full-width size (12 dots wide by 16 dots
high) or the half-width size (6 dots wide by 16 dots high).
Run-time errors:
Error code Meaning
02h
Syntax error
(BHT-3000: The two-byte Kanji mode is set by the
SCREEN
statement although you have selected the English message ver-
sion on the Set Resume menu in System Mode.)
05h
Parameter out of the range