Denso BHT-202Q Manual de usuario Pagina 100

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 407
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 99
Interleaved 2 of 5 (ITF) (I)
[Syntax]
I [:[mini.no.digits[-max.no.digits]][CD]]
The mini.no.digits and max.no.digits are the minimum and maximum numbers of barcode digits to
be read by the BHT, respectively.
These numbers must both be between 2 and 99 (inclusive) and satisfy the following condition:
mini.no.digits max.no.digits
If both mini.no.digits and max.no.digits are omitted, the default reading range will be from the
minimum number of digits specified at system mode up to 99 digits.
If only max.no.digits is omitted, the BHT will only be able to read as many digits as specified by
mini.no.digits.
CD is used to specify a check digit(s). If C is specified, barcodes are checked based on MOD-10.
The number of check digits is included in the number of digits to be read.
[Ex.] To enable the BHT to scan ITF with mini.no.digits 6, max.no.digits 10, and
MOD-10:
[VB] MyScanner.RdType = "I:6-10C"
[C#] MyScanner.RdType = "I:6-10C";
[Ex.] To enable the BHT to scan ITF with mini.no.digits 6 and max.no.digits 10 or with
mini.no.digits 20 and max.no.digits 40:
[VB] MyScanner.RdType = "I:6-10,I:20-40"
[C#] MyScanner.RdType = "I:6-10,I:20-40";