Chapter 16. Extended Functions
351
16.2.2 Detailed Function Specifications
.fcSysIGet(=1) Read numeric data from System Mode settings
Syntax:
CALL "SYSTEM.FN3" .fcSysIGet PARA%,DATA%
Description:
This function reads numeric data (DATA%) from the system menu item
specified by PARA%.
Parameter:
PARA% Item number of the system menu
Returned value:
DATA% Numeric data read from the specified system menu item
System menu items list:
Item number
(PARA%)
System menu item
Attribute
*1
DATA%, numeric data of
the system menu item
Initial
value
.sySFNlock 0 Nonlock .sySFMode 1 Shift key mode R/W
.sySF1time 1 Onetime
0
.syMkyNone 0 None
.syMkyEnt 1 Enter key
.syMkyTrg 2 Trigger switch
.syMkySF 3 Shift key
.syMkyBL 4 Backlight on/off
function key
.syM1key 2 Assignment to M1
key
R/W
- 5 (Reserved for
system)
0
.syM2key 3 Assignment to M2
key
R/W Same as above 0
.syM3key 4 Assignment to M3
key
R/W Same as above 2
.syM4key 5 Assignment to M4
key
R/W Same as above 2
.syInvtOff 0 OFF .syBarInvt 6 Black-and-white
inverted label reading
function
R/W
.syInvtOn 1 ON
0
-
7 (Reserved for
system)
-
.syDecdLvl 8 Decode level R/W 1 to 9 4
.syITFMin 9 Minimum number of
digits to be read for
ITF
R/W 2 to 20 4
.sySTFMin 10 Minimum number of
digits to be read for
STF
R/W 1 to 20 3
.syNW7Min 11 Minimum number of
digits to be read for
Codabar
R/W 3 to 20 4
R/W: Read and write possible