Denso BHT-202Q Manual de usuario Pagina 169

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 198
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 168
155
Barcode Handy Terminal
5.3.2 Communications Parameters
In System Mode and user programs written in BHT-BASIC, you can set the communications parameters
listed below.
Port IrDA Interface
Transmission speed
9600, 19200, 38400,
57600, 115200,
460800
(Note1)
bps
Character length 8 bits
Vertical parity None
Stop bit length 1 bit
Note1: 460800 bps is only possible when communicating from one BHT-900 unit to another or with the
CU-921, CU-911.
System Mode
Refer to “Chapter 4 System Operation” – “4.5.6 System Environment Settings (SET SYSTEM Menu)” for
further details.
BHT-BASIC
To set the transmission speed, character length, vertical parity, and stop bit length (For the IrDA interface,
set the transmission speed only), use the OPEN “COM:” statement in BHT-BASIC.
OPEN "COM: ..."
OPEN "COM1: ..."
Through the interface port opened by the OPEN “COM:” statement, the XFILE statement transmits a
designated file.
The communication condition can be set using the settings of the system mode. For details, refer to “4.5.6
System Environment Settings – [5] Setting the communication environment” – “5: OPEN “COM:” DETAIL”.