- 107 -
Interleaved 2of5 (ITF) (I)
[Syntax]
I [:[mini.no.digits [max. no.digits]][CD]][;[1
st
character [2
nd
character]]]
The mini.no.digits and max.no.digits are the minimum and maximum numbers of barcode digits to be
read by the BHT, respectively. These do not include the start and stop characters.
These numbers must both be between 1 and 99 (inclusive) and satisfy the following
condition:
mini.no.digits max.no.digits
If both mini.no.digits and max.no.digits are omitted, the default reading range will be from the minimum
number of digits specified at system mode up to 99 digits.
If only max.no.digits is omitted, the BHT will only be able to read as many digits as specified
by mini.no.digits.
CD is used to specify a check digit(s). If C is specified, barcodes are checked based on
MOD-10. The number of check digits is included in the number of digits to be read.
To specify multi-line code reading, first specify “&” and then specify this syntax as many
times as the number of rows to be read. In this syntax, “;” and the portion after it are valid
only for multi-line code reading. Specify a numeral (0 9) for the first and second
characters.
[Ex.] Reading 2 rows of an ITF code:
RdType = "&,I:;12,I:;23"
Vista de pagina 108